Pair tube triode for Hi-Fi made in Japan*Pairs are determined based on EM values measured with the test machine EM-604 (Yosuke Kojima)
Accessories: none
Set of 2 (the internal shape seems to be the same, but the manufacturer country print is different (made in Canada/USA), so they are not treated as a pair), brown base measurement value 44/42 (rejected value 25), getta burns, and decreases) *Measured values indicate GM values measured with the test machine TV-7 (Kojima Yosuke)
Accessories: white box
One-piece rectifier tube, fishing rod type filament made in China, incorporates the structure of the original WE274 and is well-built. Measurement value 56 (rejected value 40) with replacement box ※ The measured value shows the GM value measured with the test machine TV-7 (Kojima Yosuke)
Accessories: replacement box
Pair tube 6CA7 compatible sphere top chip date code, judged to be made by Ei based on structure, Yugoslavian measurement value 46/44 (rejected value 30) with original box*Pairs are judged based on gM values measured with the test machine TV-7 (Kojima Yosuke)
Accessories: original box
The pair tube 6CA7 compatible ball brown base double ring getter BRIMAR print is attached, but due to the structure, it seems to be made by TESLA. The measured value is 50/50 (rejected value 30), there is a getter burn with a white box ※The pair is determined based on the GM value measured with the test machine TV-7 (Kojima Yosuke)
Accessories: white box
Sold per bottle, general purpose amplifier tube, top mark, JAN, made in America, measured value 38 (rejected value 28), with replacement box (the lid of the box is missing) *The measured values are values measured with the test machine TV-7 (Kojima Yosuke)
Accessories: replacement box
Single sale rectifier tube American square getter code: 8707 measured value 44 (rejected value 40) There are few getters with original box ※The measured values indicate gM values measured with the test machine TV-7 (Kojima Yosuke)
Accessories: original box
※There is a TELEFUNKEN ECC803S, but from the structure, it was determined that the printing is CV4004, the printing is a reprint. The plate is not a box type, only one side of the rib plate is rib plate sold per bottle ECC83/M8137 equivalent tube measurement value 42 (rejection value 32) with replacement box ※ The measured value represents the GM value measured with the test machine TV-7 (Kojima Yosuke)
Accessories: replacement box
※There is a TELEFUNKEN ECC803S, but the printing was determined to be CV4004 from the structure, and the printing was determined to be a reprint. The plate is not a box type, only one side of the rib plate is caulked. Sold in 1 bottle, ECC83/M8137 equivalent tube, measured value 44 (rejected value 32) with a replacement box ※The measured value indicates the gM value measured by the testing machine TV-7 (Kojima Yosuke)
Accessories: replacement box
Pair tube 6BQ5 compatible ball pentode tube measurement value 66/66 (rejection value 50) with original box SIEMENS print is printed, but it was determined from the structure and date code that it was made by Ei (made in Yugoslavia) ※The pair was determined based on GM values measured with the TV-7 testing machine (Kojima Yosuke)
Accessories: original box
Pair tube, 6BQ5 compatible ball, made in Yugoslavia, foot, measured value 70/70 (rejected value 50) with original box ※ pair is determined based on GM values measured with test machine TV-7 (Kojima Yosuke)
Accessories: original box
The diamond mark on the bottom of the 12AU7 compatible ball sold per bottle was not confirmed, but it was determined that it was the original ECC82 from the internal structure. Measured value 102 (rejected value 56) with white box ※The measured value shows the gM value measured with the test machine TV-7 (Kojima Yosuke)
Accessories: white box
※There is a TELEFUNKEN ECC803S, but from the structure, it was determined that the printing was a reprint. The plate is not a box type, only one side of the rib plate is rib plate sold per bottle ECC83/M8137 equivalent tube measurement value 38 (rejection value 32) with replacement box ※ The measured value represents the GM value measured with the test machine TV-7 (Kojima Yosuke)
Accessories: replacement box
Pair tube 6BQ5 compatible ball pentode tube made in Russia, black plate, measured value 78/72 (rejection value 50) with original box ※ pair is determined based on GM values measured with test machine TV-7 (Kojima Yosuke)
Accessories: original box
Pair tube, large beam output tube, 8147 compatible bulb, gray plate for Hi-Fi, with original box (outer box/inner box), has slightly decreased getter for both tubes ※ The pair measures and determines EM values with the measuring machine TC-162 (Kojima Yosuke)
Accessories: original box
Pair tube KT88 compatible sphere Russian metal brown base measurement value 50/50 (rejection theory 44) there is writing on the base with the blue box ※The pair is determined based on the GM value measured with the test machine TV-7 (Kojima Yosuke)
Accessories: blue box
※There is a TELEFUNKEN ECC803S, but the printing was determined to be CV4004 based on the structure. The plate is not a box type, only one side of the rib plate is caulked. Sold in 1 bottle, ECC83/M8137 equivalent tube, measured value 36 (rejected value 32) with replacement box ※The measured value indicates the gM value measured by the testing machine TV-7 (Kojima Yosuke)
Accessories: replacement box
Pair tube 6CA7 compatible ball tea base made in Slovakia lot: 9825/9825 measured value 56/56 (rejected value 30) with white box*Pairs are judged based on GM values measured with the TV-7 testing machine (Kojima Yosuke)
Accessories: white box
Pair tube 6SL7 equivalent tube military tube brown base ring getter measurement value 52 (rejected value 32) with original box ※The measured value shows the gm value measured with the test machine TV-7 (Kojima Yosuke)
Accessories: original box
Sold 1 bottle EF86/6267 compatible ball, military high reliability tube mesh measurement value 46 (rejected value 33), seems to be made by GEC due to the structure. Comes with a white box ※The measured values indicate GM values measured with the testing machine TV-7 (Kojima Yosuke)
Accessories: white box
Pair tube 6BQ5 high reliability tube made in Japan measured value 72/68 (rejection value 46) *Pairs are determined based on GM values measured with the TV-7 test machine (Kojima Yosuke)
Accessories: none
Pair tube, subthermal beam tube, made in China, seems to have been used in the company's power amplifiers, etc. Measured value 64/64 (rejected value 44) with replacement box*Pairs are determined based on gM values measured by the testing machine TV-7 (Kojima Yosuke)
Accessories: replacement box
Pair Tube Bi-triode Power Tube Made in USA JAN Measurement Value 60/60 (Rejection Value 40) With Original Box ※ The pair is judged based on GM value measured on the tv-7 test machine (Yosuke Kojima)
Accessories: original box
Pair tube, subthermal beam tube, made in China, seems to have been used in the company's power amplifiers, etc. Measured value 66/64 (rejected value 44) with replacement box*Pairs are determined based on gM values measured by the testing machine TV-7 (Kojima Yosuke)
Accessories: replacement box
Pair Tube Bi-triode Power Tube Made in USA JAN Measurement Value 60/60 (Rejection Value 40) With Original Box ※ The pair is judged based on GM value measured on the tv-7 test machine (Yosuke Kojima)
Accessories: original box
Pair tube, EL84 compatible ball, pentode tube, made in Japan, measured value 84/80 (rejection value 50), both tubes have pin bends ※ pairs are determined based on GM values measured with test machine TV-7 (Kojima Yosuke)
Accessories: none
Pair Tube Bi-triode Power Tube Made in USA JAN Measurement Value 60/60 (Rejection Value 40) With Original Box ※ The pair is judged based on GM value measured on the tv-7 test machine (Yosuke Kojima)
Accessories: original box
Pair tube (checked with a tube checker) beam quadrupole. There is a tea box. Measured value 36,34/30 (rejection value) *The pair was determined based on the GM value measured by the testing machine TV-7. The ※ logo is scratched, so it's a bargain.
※Set of 2 (not treated as a pair since the internal shape is different between the tubes) KT88 compatible balls, Russian metal brown, base code: 0210/0601 measured value 56/50 (rejection theory 44) with original box ※ measured values indicate GM values measured with the TV-7 testing machine (Kojima Yosuke)
Accessories: original box
Pair tube, EL34 compatible ball, Russian tube, measured value 44/42 (rejected value 30) with original box ※ pair is determined based on GM values measured with test machine TV-7 (Kojima Yosuke)
Accessories: original box